Twenty‐Four‐Hour Central Ambulatory Blood Pressure: Relationship With Measures of Cardiovascular Subclinical Organ Damage in Healthy Individuals

  • Ing Ni Lu
  • , Shikai Yu
  • , Gisele J. Bentley
  • , Barry J. McDonnell
  • , Navazh Jalaludeen
  • , Kaisa M. Mäki‐Petäjä
  • , Joseph Cheriyan
  • , Ian B. Wilkinson
  • , Carmel M. McEniery

Research output: Contribution to journalArticlepeer-review

Abstract

Background In most, but not all, observational studies, ambulatory central systolic blood pressure (cSBP) is more closely related to left ventricular mass index than ambulatory brachial SBP. However, the association with other markers of subclinical organ damage is poorly understood. We investigated the association between ambulatory brachial SBP or cSBP and measures of subclinical organ damage, together with the influence of waveform calibration method, in a large community‐based population of untreated individuals. Methods In all, 1311 participants (mean age, 45±18 years; 589 women) had simultaneous measurements of ambulatory brachial and central pressure over 24 hours. Of these, left ventricular mass index was assessed in 675 individuals, carotid intima‐media thickness in 610 individuals and carotid–femoral (aortic) pulse‐wave velocity in 1091 individuals. Results Left ventricular mass index was most strongly associated with cSBP, calibrated using mean and diastolic blood pressure, with a β coefficient of 0.237 (95% CI, 0.225–0.453; P <0.001). The adjusted (partial) correlation coefficient for this association was also significantly higher versus both brachial SBP and cSBP derived from calibration using SBP and diastolic blood pressure ( P <0.001 for both). The same was true for carotid intima‐media thickness (β coefficient=0.141 [95% CI, 0.777–2.502]; P <0.001), although the adjusted correlation coefficients did not differ significantly between ambulatory blood pressure indices. In contrast, aortic pulse‐wave velocity shared a similar association with both brachial and central ambulatory pressure, with no obvious effect of waveform calibration method. Conclusions Ambulatory cSBP may provide valuable additional information concerning cardiovascular risk, although the method of waveform calibration exerts a marked impact.
Original languageEnglish
JournalJournal of the American Heart Association
Volume15
Issue number1
Early online date30 Dec 2025
DOIs
Publication statusPublished - 30 Dec 2025

Keywords

  • Adult
  • Aged
  • Blood Pressure
  • Blood Pressure Monitoring, Ambulatory
  • Brachial Artery - physiopathology
  • Cardiovascular Diseases - physiopathology - diagnosis
  • Carotid Intima-Media Thickness
  • Carotid-Femoral Pulse Wave Velocity
  • Female
  • Humans
  • Hypertrophy, Left Ventricular - physiopathology - diagnosis
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Pulse Wave Analysis
  • Time Factors
  • ambulatory brachial systolic blood pressure
  • ambulatory central systolic blood pressure
  • aortic pulse‐wave velocity
  • carotid intima‐media thickness
  • left ventricular mass index