TY - JOUR
T1 - Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques
AU - Bibb, R. J.
AU - Eggbeer, D.
AU - Williams, R. J.
AU - Woodward, A.
PY - 2006/7
Y1 - 2006/7
N2 - Previous studies of CAD/CAM-produced sacrificial patterns for removable partial denture frameworks have been documented but to date, no such restorations have been test-fitted to a patient. This paper provides details of the first trial fitting to a patient of an RPD framework, the sacrificial pattern of which was produced by CAD/CAM and RP technologies. A cast of the patient was scanned and the normal procedures of dental surveying and pattern build were undertaken with reference to the scanned model using computer-aided design. A sacrificial pattern of the design was produced by rapid prototyping technology. After spruing the pattern, investment-casting and finishing techniques were carried out according to conventional principles. The framework was successfully trial-fitted to the patient and clinically judged to be acceptable for the next stage of denture fabrication, that of adding acrylic bases and artificial teeth.
AB - Previous studies of CAD/CAM-produced sacrificial patterns for removable partial denture frameworks have been documented but to date, no such restorations have been test-fitted to a patient. This paper provides details of the first trial fitting to a patient of an RPD framework, the sacrificial pattern of which was produced by CAD/CAM and RP technologies. A cast of the patient was scanned and the normal procedures of dental surveying and pattern build were undertaken with reference to the scanned model using computer-aided design. A sacrificial pattern of the design was produced by rapid prototyping technology. After spruing the pattern, investment-casting and finishing techniques were carried out according to conventional principles. The framework was successfully trial-fitted to the patient and clinically judged to be acceptable for the next stage of denture fabrication, that of adding acrylic bases and artificial teeth.
KW - Computer-aided design
KW - Rapid prototyping
KW - Removable partial denture
UR - http://www.scopus.com/inward/record.url?scp=33846295209&partnerID=8YFLogxK
U2 - 10.1243/09544119JEIM62
DO - 10.1243/09544119JEIM62
M3 - Article
C2 - 17117768
AN - SCOPUS:33846295209
SN - 0954-4119
VL - 220
SP - 793
EP - 797
JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
IS - 7
ER -