TY - JOUR
T1 - The influence of ramp rate on V̇O2peak and "excess" V̇O2 during arm crank ergometry
AU - Smith, P. M.
AU - Amaral, I.
AU - Doherty, M.
AU - Price, M. J.
AU - Jones, A. M.
PY - 2006/8
Y1 - 2006/8
N2 - The principal aim of this study was to examine how different ramp rates influenced the attainment of peak physiological responses during incremental arm crank ergometry (ACE). Additionally, the study examined whether there was any evidence for the development of an "excess" V̇O2 during ACE due to upward curvi-linearity in the V̇O2-work rate relationship, and whether this was influenced by the ramp rate. Sixteen physically active, though non-specifically trained, men (mean ±s age 30 ± 8 years; height 1.79 ± 0.07 m; body mass 84.7 ± 13.2 kg) volunteered to participate. Having completed a familiarisation test, all subjects returned to the laboratory to complete two ramp tests on an electrically-braked ergometer in a counter-balanced order. Both ramp tests started at 60 W with work rate subsequently incremented by either 6 or 12 W·min-1. Pulmonary gas exchange was measured breath-by-breath throughout the tests. Subjects achieved a greater final work rate during the 12 W±min-1 test compared to the 6 W·min-1 test (168 ± 28 vs. 149 ± 26 W; p < 0.001). The V̇O 2peak (3.06 ± 0.65 vs. 2.96 ± 0.48 L·min -1; p = 0.27), HRpeak (179 ± 15 vs. 177 ± 16 b·min-1; p = 0.17) and V̇Epeak (112 ± 22 vs. 105 ± 16 L·min-1; p = 0.09) were not different between the tests, but V̇CO2peak (3.54 ± 0.64 vs. 3.27 ± 0.46 L·min-1; p = 0.01) RERpeak (1.17 ± 0.07 vs. 1.11 ± 0.06; p < 0.001), and end-exercise blood (lactate) (11.9 ± 2.1 vs. 10.8 ± 2.6 mmol·L-1 ; p = 0.005) were all higher in the 12 W·min-1 test. An "excess" V̇O2 was observed in 13 out of 16 tests at 12 W·min-1 and in 15 out of 16 tests at 6 W·min -1. Neither the magnitude of the "excess" V·O 2 (0.42 ± 0.41 vs. 0.37 ± 0.18 L̇min-1; p = 0.66) nor the V̇O2 at which the V̇O2-work rate relationship departed from linearity (2.17 ± 0.34 vs. 2.18 ± 0.32 L̇min-1; p = 0.94) were significantly different between the two ramp tests. These data indicate that differences in ramp rate within the range of 6-12 Ẇmin-1 influence the peak values of work rate, V̇CO2 and RER, but do not influence peak values of V̇O 2 or HR during ACE. The development of an "excess" V̇O2 appears to be a common feature of ramp exercise in ACE, although the mechanistic basis for this effect is presently unclear.
AB - The principal aim of this study was to examine how different ramp rates influenced the attainment of peak physiological responses during incremental arm crank ergometry (ACE). Additionally, the study examined whether there was any evidence for the development of an "excess" V̇O2 during ACE due to upward curvi-linearity in the V̇O2-work rate relationship, and whether this was influenced by the ramp rate. Sixteen physically active, though non-specifically trained, men (mean ±s age 30 ± 8 years; height 1.79 ± 0.07 m; body mass 84.7 ± 13.2 kg) volunteered to participate. Having completed a familiarisation test, all subjects returned to the laboratory to complete two ramp tests on an electrically-braked ergometer in a counter-balanced order. Both ramp tests started at 60 W with work rate subsequently incremented by either 6 or 12 W·min-1. Pulmonary gas exchange was measured breath-by-breath throughout the tests. Subjects achieved a greater final work rate during the 12 W±min-1 test compared to the 6 W·min-1 test (168 ± 28 vs. 149 ± 26 W; p < 0.001). The V̇O 2peak (3.06 ± 0.65 vs. 2.96 ± 0.48 L·min -1; p = 0.27), HRpeak (179 ± 15 vs. 177 ± 16 b·min-1; p = 0.17) and V̇Epeak (112 ± 22 vs. 105 ± 16 L·min-1; p = 0.09) were not different between the tests, but V̇CO2peak (3.54 ± 0.64 vs. 3.27 ± 0.46 L·min-1; p = 0.01) RERpeak (1.17 ± 0.07 vs. 1.11 ± 0.06; p < 0.001), and end-exercise blood (lactate) (11.9 ± 2.1 vs. 10.8 ± 2.6 mmol·L-1 ; p = 0.005) were all higher in the 12 W·min-1 test. An "excess" V̇O2 was observed in 13 out of 16 tests at 12 W·min-1 and in 15 out of 16 tests at 6 W·min -1. Neither the magnitude of the "excess" V·O 2 (0.42 ± 0.41 vs. 0.37 ± 0.18 L̇min-1; p = 0.66) nor the V̇O2 at which the V̇O2-work rate relationship departed from linearity (2.17 ± 0.34 vs. 2.18 ± 0.32 L̇min-1; p = 0.94) were significantly different between the two ramp tests. These data indicate that differences in ramp rate within the range of 6-12 Ẇmin-1 influence the peak values of work rate, V̇CO2 and RER, but do not influence peak values of V̇O 2 or HR during ACE. The development of an "excess" V̇O2 appears to be a common feature of ramp exercise in ACE, although the mechanistic basis for this effect is presently unclear.
KW - Exercise testing
KW - O uptake
KW - V̇O kinetics
KW - V̇O slow component
UR - http://www.scopus.com/inward/record.url?scp=33747144130&partnerID=8YFLogxK
U2 - 10.1055/s-2005-865857
DO - 10.1055/s-2005-865857
M3 - Article
C2 - 16874587
AN - SCOPUS:33747144130
SN - 0172-4622
VL - 27
SP - 610
EP - 616
JO - International Journal of Sports Medicine
JF - International Journal of Sports Medicine
IS - 8
ER -