TY - JOUR
T1 - Acceptability and feasibility of implementing accelorometry-based activity monitors and a linked web portal in an exercise referral scheme
T2 - feasibility randomized controlled trial
AU - Hawkins, Jemma
AU - Charles, Joanna M.
AU - Edwards, Michelle
AU - Hallingberg, Britt
AU - Mcconnon, Linda
AU - Edwards, Rhiannon Tudor
AU - Jago, Russell
AU - Kelson, Mark
AU - Morgan, Kelly
AU - Murphy, Simon
AU - Oliver, Emily J.
AU - Simpson, Sharon A.
AU - Moore, Graham
N1 - Publisher Copyright:
© 2019 Journal of Medical Internet Research. All rights reserved.
PY - 2018/10/5
Y1 - 2018/10/5
N2 - Background: Exercise referral schemes (ERSs) are recommended for patients with health conditions or risk factors. Evidence points to the initial effectiveness and cost-effectiveness of such schemes for increasing physical activity, but effects often diminish over time. Techniques such as goal setting, self-monitoring, and personalized feedback may support motivation for physical activity and maintenance of effects. Wearable technologies could provide an opportunity to integrate motivational techniques into exercise schemes. However, little is known about acceptability to exercise referral populations or implementation feasibility within exercise referral services. Objective: To determine the feasibility and acceptability of implementing an activity-monitoring device within the Welsh National ERS to inform a decision on whether and how to proceed to an effectiveness trial. Methods: We conducted a feasability randomized controlled trial with embedded mixed-methods process evaluation and an exploratory economic analysis. Adults (N=156) were randomized to intervention (plus usual practice; n=88) or usual practice only (n=68). Usual practice was a 16-week structured exercise program. The intervention group additionally received an accelerometry-based activity monitor (MyWellnessKey) and associated Web platform (MyWellnessCloud). The primary outcomes were predefined progression criteria assessing acceptability and feasibility of the intervention and proposed evaluation. Postal questionnaires were completed at baseline (time 0:T0), 16 weeks (T1), and 12 months after T0 (T2). Routine data were accessed at the same time-points. A subsample of intervention participants and scheme staff were interviewed following the initiation of intervention delivery and at T2. Results: Participants were on average aged 56.6 (SD 16.3) years and mostly female (101/156, 64.7%) and white (150/156, 96.2%). Only 2 of 5 progression criteria were met; recruitment and randomization methods were acceptable to participants, and contamination was low. However, recruitment and retention rates (11.3% and 67.3%, respectively) fell substantially short of target criteria (20% and 80%, respectively), and disproportionally recruited from the least deprived quintile. Only 57.4% of intervention participants reported receipt of the intervention (below the 80% progression threshold). Less than half reported the intervention to be acceptable at T2. Participant and staff interviews revealed barriers to intervention delivery and engagement related to the device design as well as context-specific technological challenges, all of which made it difficult to integrate the technology into the service. Routinely collected health economic measures had substantial missing data, suggesting that other methods for collecting these should be used in future. Conclusions: To our knowledge, this is the first study to evaluate short- And long-term feasibility and acceptability of integrating wearable technologies into community-based ERSs. The findings highlight device- And context-specific barriers to doing this in routine practice, with typical exercise referral populations. Key criteria for progression to a full-scale evaluation were not met.
AB - Background: Exercise referral schemes (ERSs) are recommended for patients with health conditions or risk factors. Evidence points to the initial effectiveness and cost-effectiveness of such schemes for increasing physical activity, but effects often diminish over time. Techniques such as goal setting, self-monitoring, and personalized feedback may support motivation for physical activity and maintenance of effects. Wearable technologies could provide an opportunity to integrate motivational techniques into exercise schemes. However, little is known about acceptability to exercise referral populations or implementation feasibility within exercise referral services. Objective: To determine the feasibility and acceptability of implementing an activity-monitoring device within the Welsh National ERS to inform a decision on whether and how to proceed to an effectiveness trial. Methods: We conducted a feasability randomized controlled trial with embedded mixed-methods process evaluation and an exploratory economic analysis. Adults (N=156) were randomized to intervention (plus usual practice; n=88) or usual practice only (n=68). Usual practice was a 16-week structured exercise program. The intervention group additionally received an accelerometry-based activity monitor (MyWellnessKey) and associated Web platform (MyWellnessCloud). The primary outcomes were predefined progression criteria assessing acceptability and feasibility of the intervention and proposed evaluation. Postal questionnaires were completed at baseline (time 0:T0), 16 weeks (T1), and 12 months after T0 (T2). Routine data were accessed at the same time-points. A subsample of intervention participants and scheme staff were interviewed following the initiation of intervention delivery and at T2. Results: Participants were on average aged 56.6 (SD 16.3) years and mostly female (101/156, 64.7%) and white (150/156, 96.2%). Only 2 of 5 progression criteria were met; recruitment and randomization methods were acceptable to participants, and contamination was low. However, recruitment and retention rates (11.3% and 67.3%, respectively) fell substantially short of target criteria (20% and 80%, respectively), and disproportionally recruited from the least deprived quintile. Only 57.4% of intervention participants reported receipt of the intervention (below the 80% progression threshold). Less than half reported the intervention to be acceptable at T2. Participant and staff interviews revealed barriers to intervention delivery and engagement related to the device design as well as context-specific technological challenges, all of which made it difficult to integrate the technology into the service. Routinely collected health economic measures had substantial missing data, suggesting that other methods for collecting these should be used in future. Conclusions: To our knowledge, this is the first study to evaluate short- And long-term feasibility and acceptability of integrating wearable technologies into community-based ERSs. The findings highlight device- And context-specific barriers to doing this in routine practice, with typical exercise referral populations. Key criteria for progression to a full-scale evaluation were not met.
KW - Accelerometry
KW - Activity trackers
KW - Costs
KW - Economic evaluation
KW - Exercise
KW - Exercise referral
KW - Feasibility studies
KW - Fitness trackers
KW - Physical activity
KW - Wearable technologies
UR - http://www.scopus.com/inward/record.url?scp=85064126742&partnerID=8YFLogxK
U2 - 10.2196/12374
DO - 10.2196/12374
M3 - Article
C2 - 30924791
AN - SCOPUS:85064126742
SN - 1438-8871
VL - 21
JO - Journal of Medical Internet Research
JF - Journal of Medical Internet Research
IS - 3
M1 - e12374
ER -