TY - JOUR
T1 - Sustained Shear Stress Reveals Agreement between Flow-Mediated Dilation and Flow-Mediated Slowing
AU - Stoner, Lee
AU - McDonnell, Barry
AU - Fryer, Simon
AU - Griffiths, Thomas
AU - Faulkner, James
AU - Williams, Abbie Rhian
AU - Pugh, Christopher
AU - Zieff, Gabriel
AU - Chauntry, Aiden J.
AU - Paterson, Craig
AU - Stone, Keeron
N1 - Publisher Copyright:
© The Author(s) 2026. Published by S. Karger AG.
PY - 2026/8/5
Y1 - 2026/8/5
N2 - Introduction: Flow-mediated slowing (FMS), the decrease in pulse wave velocity (PWV) in response to elevated shear stress, is a simpler, operator-independent alternative to assessing arterial diameter (DIA) increase via flow-mediated dilation (FMD). Traditional flow-mediated assessment uses reactive hyperemia, yet sustained shear (ss) stress is a more ubiquitous in vivo physiological occurrence. This study aimed to determine the agreement between sustained-shear FMD (ssFMD) and sustained-shear FMS (ssFMS) in response to a sustained shear stress stimulus designed to enhance endothelial function. Methods: In 19 participants (12 male, 28 ± 8 years), brachial artery DIA and brachial-radial PWV were measured in experimental and control arms. Following baseline, sustained stepwise increases in shear rate were induced using upper-limb heating (10 min) at 47.5°c and 52.5°c, and handgrip exercise (4 min) at 0.33 Hz and 0.67 Hz in the experimental arm. The agreement was tested by modeling the overall association using a linear mixed-effects model. Results: The sustained shear protocol elicited a large increase in mean shear rate in the experimental arm (Δ 299 1/s, p < 0.001). This resulted in a significant time × condition interaction in the experimental arm, with a moderate increase in DIA (Δ 0.04 cm, ∼13%; p < 0.001) and a moderate decrease in PWV (Δ −1.7 m/s, ∼20%; p < 0.001). There was a significant within-person inverse association between ssFMD and ssFMS (β = −0.200, p < 0.001) in the experimental arm. Conclusion: ssFMS demonstrates a response consistent with ssFMD following a sustained shear stress protocol. Findings support ssFMS as a viable tool for assessing acute improvements in endothelial function
AB - Introduction: Flow-mediated slowing (FMS), the decrease in pulse wave velocity (PWV) in response to elevated shear stress, is a simpler, operator-independent alternative to assessing arterial diameter (DIA) increase via flow-mediated dilation (FMD). Traditional flow-mediated assessment uses reactive hyperemia, yet sustained shear (ss) stress is a more ubiquitous in vivo physiological occurrence. This study aimed to determine the agreement between sustained-shear FMD (ssFMD) and sustained-shear FMS (ssFMS) in response to a sustained shear stress stimulus designed to enhance endothelial function. Methods: In 19 participants (12 male, 28 ± 8 years), brachial artery DIA and brachial-radial PWV were measured in experimental and control arms. Following baseline, sustained stepwise increases in shear rate were induced using upper-limb heating (10 min) at 47.5°c and 52.5°c, and handgrip exercise (4 min) at 0.33 Hz and 0.67 Hz in the experimental arm. The agreement was tested by modeling the overall association using a linear mixed-effects model. Results: The sustained shear protocol elicited a large increase in mean shear rate in the experimental arm (Δ 299 1/s, p < 0.001). This resulted in a significant time × condition interaction in the experimental arm, with a moderate increase in DIA (Δ 0.04 cm, ∼13%; p < 0.001) and a moderate decrease in PWV (Δ −1.7 m/s, ∼20%; p < 0.001). There was a significant within-person inverse association between ssFMD and ssFMS (β = −0.200, p < 0.001) in the experimental arm. Conclusion: ssFMS demonstrates a response consistent with ssFMD following a sustained shear stress protocol. Findings support ssFMS as a viable tool for assessing acute improvements in endothelial function
KW - endothelial function
KW - flow-mediated dilation
KW - Flow-mediated slowing
KW - arterial stiffness
KW - Pulse wave velocity
UR - https://www.scopus.com/pages/publications/105054316122
U2 - 10.1159/pls/aeoag002
DO - 10.1159/pls/aeoag002
M3 - Article
AN - SCOPUS:105054316122
SN - 2235-8668
VL - 14
SP - 158
EP - 168
JO - Pulse
JF - Pulse
IS - 1
ER -