Crynodeb
This paper provides a straightforward design method for achieving a maximum wavelength resolution for an edge filter-based ratiometric system. An analysis of the influence of a range of factors on the resolution of the ratiometric wavelength measurement system was carried out. The investigation shows that, for a given input optical signal and when the working wavelength range is known, it is relatively straightforward to select an optimum slope for the edge filter that will yield a maximum resolution for the system. An experimental verification is carried out using a tunable laser and three macrobending fibre edge filters, with a good match between experimental and simulation results.
Iaith wreiddiol | Saesneg |
---|---|
Tudalennau (o-i) | 1032-1037 |
Nifer y tudalennau | 6 |
Cyfnodolyn | Optics and Laser Technology |
Cyfrol | 42 |
Rhif cyhoeddi | 6 |
Dynodwyr Gwrthrych Digidol (DOIs) | |
Statws | Cyhoeddwyd - Medi 2010 |
Cyhoeddwyd yn allanol | Ie |